The Malvern Range of Compact Pump Systems
for Wastewater Applications |
Specification
| Chamber Type |
Chamber Dia. |
Chamber Height |
Base to Centre of Inlet |
Base to Centre of Outlet |
Inlet Dia. |
Outlet Fitting for MDPE Pipe |
| A |
690 |
720-920 |
340 |
350 |
100/150 |
63 |
| B |
530 |
670-800 |
340 |
350 |
100 |
50 |
Installation & Operation
The access neck and cover are universally adjustable in height
and can be rotated to allow easy alignment with flooring and
landscaping design, independent of the inflow or discharge
line directions.
A protective cover for the access neck is supplied for use
during installation to prevent backfill from damaging the
access cover.
Access neck extension piece is available as part of the
package to facilitate a further 150mm inlet depth if required.

Click here to read more.

|
| |
|
New for 2008, Klargester's renowned HillMaster range is
joined by the Malvern series of compact pump stations.
Designed for rapid installation, the chambers provide simple
and speedy dewatering of buildings and areas below the
sewer level and are suitable for pumping wastewater in
accordance with DIN/EN 12056.
Applications
- Outbuildings and extensions
- Cellars
- External WCs
- Pool houses
Chambers are suitable for effluent and sewage dependent on
pump specification, required distance and lift.
Features
- Ready for simple and immediate installation
- Fully adjustable for height and floor level alignment
- Non-return valves as standard
- Protective cover for protection during installation
- Manufactured from tough polyethylene
- Corrosion resistant
- Outlet pipe compression fittings as standard
Sewage Pump Performance
Chamber A (40mm solids handling)

Effluent Pump Performance

Design
All Malvern systems consist of a polyethylene chamber fitted
with a quality pump, float switch, non-return valves, pedestrian
duty cover and frame, cover plate and all connections.
|
| |
|
 |

 |
A Range of Waste Water and Sewage Package Pump Systems and Pumping Stations for Residential &
Commercial Developments
Applications
Developments where foul drainage by gravity is not possible,
including:
- Domestic sewage pumping
- Effluent pumpsets for sewage treatment plants
- Surface water pumping systems
- Septic tank pumpsets
- 24 hour storage chambers
- Bespoke systems
|
| |
|
Features
|
 |
Advice
|
- Complete package systems delivered direct to site
- Ready for immediate and simple installation
- Factory built and quality assured
- Maintenance free GRP and polyethylene chambers
- High-level alarm fitted as standard
- Full Klargester after sales maintenance available
Design
All standard Klargester package pump systems are supplied
with GRP/polyethylene chambers, pump(s), high-level alarm,
pre-set automatic level control, non-return valve, discharge
pipe and all connections.
Options
- Wide range of emergency overflow tanks
- 110mm or 160mm inlet connections
- Various invert depths
- Standby replacement pumps
Bespoke Systems
Klargester manufactures pumping chambers of various diameter
and depths, with pumps, guide rails and control equipment
fitted as per the client’s specification.
Please contact us direct and we will be pleased to quote against
your specific requirements.
|
|
The information in this sales literature is, by necessity,
brief. For more detailed technical literature and drawings
regarding applications, installation, maintenance or specific
options, please contact Klargester.
We have both internal and field sales staff who will be pleased
to assist.
See Legislations for
more information regarding regulations.
Maintenance
Klargester package pump systems are designed for minimum
maintenance.
Klargester offers a full after sales service involving planned
maintenance visits on the U.K. mainland.
Legal Requirements
Prior to installation, there is a legal requirement to obtain
permission from the appropriate agencies (including connection
to a public sewer).
Delivery & Installation
Units are normally delivered by flat bed vehicle and cranage
facilities should be available on-site for off loading. Installation
is quick and economical, the unit requiring only a concrete
base and surround. Comprehensive installation instructions
are supplied with every unit. |
|
|
|
|
24hr Storage to Meet Building Regulations
The Klargester HillMaster24 pump station range has been
designed in accordance with Building Regulations Document
H1 Foul Drainage, page 16. (Pumping Installations) Section
2.39. This states:
"Where
foul drainage from a building is to be pumped, the effluent
receiving chamber
should be sized to contain 24 hour inflow to allow for disruption
in service. The minimum daily
discharge of foul drainage should be taken as 150 litres per
head per day for domestic use.
For other types of building, the capacity of the receiving
chamber should be based on the
calculated daily demand of the water intake for the building.
Where only a proportion of the
foul sewage is to be pumped, then the capacity should be based
pro-rata. In all pumped
systems the controls should be so arranged to optimise pump
operation. The required 150
litres per head per day volume should reflect the storage
volume in the station pump or
station and overflow tanks."
|
|
|
|
|
Product Range
|
|
|
|
|
|
|
HillMaster
The HillMaster range offers a competitive solution to the
pumping requirements of both domestic and industrial applications.
Often it can be preferable to keep civil work and installation
costs down to a minimum but such economy should not mean any
shortfall in quality.
The Chiltern range is manufactured in tough polyethylene using
advanced rotational-moulding technology, while the Pennine,
Cairngorm and Mendip ranges are made from maintenance-free
GRP. All units are engineered with the highest quality parts
and fittings.
- High-level alarm as standard (optional as marked *)
- Various invert depths
- Internal lifting chains and guiderails (as specified)
- Wide range of pump options including grinders/macerators
- Pedestrian/vehicle covers
+
Click here to view the HillMaster range
|
|
|
|
|
HillMaster24
The HillMaster24 range has been specifically designed to
meet the requirements of Building Regulations Document H1
Foul Drainage. This regulation recognises the need for pump
stations to have a 24hr storage capacity in case of a disruption
in service (such as a power failure).
This comprehensive range offers an advanced solution to larger
domestic and industrial applications. For large-capacity flows
(such as stormwater run-off from hard-standing areas), horizontal
holding chambers are available in a comprehensive range of
sizes.
- High-level alarm fitted as standard
- Various invert depths
- Internal lifting chains and guiderails fitted as standard
- Wide range of pump options including grinders/macerators
- Combined chamber capacity up to 90,000 litres
- Pumping distances up to 1000 metres
- Pedestrian/vehicle covers
+
Click here to view the HillMaster24 range
|
|
|
|
|
Effluent Pumpsets
A septic tank or treatment system pumpset can be used to
disperse settled effluent when a site has a high water table
or adverse invert levels. Installed after the septic tank
or treatment system and pumping settled effluent up to an
inspection chamber, flow to the drainage system then takes
place by gravity in the normal way.

Domestic Sewage Pumpsets
If the main sewer is accessible but at a higher level to
(or some distance from) the domestic foul drain, then a domestic
sewage pumpset may be used to pump unsettled sewage directly
to the main. Whilst single pump units are acceptable for individual
houses, it is recommended that twin pumping systems be used
for multiple dwellings.

Surface Water Pumpsets
Due to the amount of rainwater that can fall in a short
time period, Surface Water run-off is often the most demanding
of all applications, whether hard-standing or roof areas.
Klargester offers a comprehensive range of packaged pump systems
in both standard form or manufactured to bespoke specifications.
Careful calculation of the run-off areas is essential when
sizing these pump systems.
|
|
|
Key Points to Consider
Firstly, don’t worry.
Klargester have a team of pump experts on hand to advise
you on the correct product for your site. All we need
from you is information on key factors such as:
- Application: e.g domestic
residential / commercial
- Sewage, Effluent or Surface
water?
- Inlet depth (below ground
level)
- Pumping distance + lift
- Electrical supply
Simply give us a ring or click
here to download our Package Pumps Enquiry
form. This form will guide you on what measurements
you will need and any additional data. Once completed,
phone, email, fax or post it back to us and our team
will provide you with a solution.
|

|
|
|
|
|

|
|
|
|
|
|
|
|
 |